Before a laboratory or genomic result can be trusted, regulators want proof that the underlying sample met quality standards. The Biospecimen Findings domain, BS, captures specimen volume, pH, hemolysis indices, and RNA Integrity Numbers. Mapping BS establishes objective pre-analytical quality thresholds across multi-center trials, ensuring compromised samples are flagged before downstream biomarker analyses.
Clinical Variable Mapping Scope & Service Execution
Captures physical and quality characteristics of biological specimens (volume, pH, hemolysis index, cell viability, RIN score) prior to downstream lab or genomic testing.
In immuno-oncology and cell therapy trials, quantifying T-cell subsets, NK cells, and surface markers drives mechanism-of-action proof. The Cell Phenotyping Findings domain, CP, standardizes flow cytometry and CyTOF measurements alongside exact cell populations and parent gating denominators. Accurate CP mapping prevents gating ambiguity across central labs and turns complex cytometry exports into submission-ready immunological endpoints.
Clinical Variable Mapping Scope & Service Execution
Standardizes flow cytometry, CyTOF, and immunophenotyping assays quantifying cell populations, surface marker expression (CD4+, CD8+, NK cells), and viability.
Cardiotoxicity monitoring often requires specialized assessments beyond standard vital signs and ECGs, such as echocardiographic ejection fractions or cardiac MRI metrics. The Cardiovascular System Findings domain, CV, isolates these structural and hemodynamic measurements with anatomical locations and imaging methods. Clean CV mapping keeps cardiac function endpoints structured and distinct from routine blood pressure checks.
Clinical Variable Mapping Scope & Service Execution
Captures non-ECG cardiovascular assessments including echocardiography (LVEF, fractional shortening), cardiac MRI, angiography, and ambulatory blood pressure metrics.
An investigational drug cannot demonstrate efficacy if patients never take it. The Drug Accountability domain, DA, tracks every tablet, capsule, or vial dispensed, returned, lost, or destroyed at each clinic visit. Standardizing DA units across dispensing and return records allows biostatisticians to compute exact treatment compliance percentages without manual unit conversions.
Clinical Variable Mapping Scope & Service Execution
Tracks investigational product dispensed, returned, lost, or destroyed at each clinic visit to calculate patient adherence and compliance percentages.
When a subject dies during or after a clinical trial, regulatory reviewers examine every detail surrounding the event. The Death Details domain, DD, standardizes primary and secondary causes of death, autopsy status, and clinical assessments. Rigorous DD mapping guarantees complete date alignment across Demographics, Disposition, and fatal Adverse Events—preventing critical regulatory inconsistencies.
Clinical Variable Mapping Scope & Service Execution
Captures supplemental mortality details—primary/secondary causes of death, autopsy status, and relationship to study drug—when a subject dies during or after the trial.
Cardiac safety and QT prolongation assessments are mandatory checkpoints for nearly every new therapeutic molecule. The ECG Test Results domain, EG, standardizes PR, QRS, QT, and QTcF intervals alongside lead placement, supine positioning, and exact post-dose timepoints. Mapping EG with individual replicate records allows pharmacometricians to model concentration-QTc relationships with regulatory precision.
Clinical Variable Mapping Scope & Service Execution
Standardizes 12-lead and Holter electrocardiogram parameters (PR, QRS, QT, QTcF, QTcB, ventricular rate, rhythm interpretations) across centralized and local reads.
Objective physical performance—how far a patient walks in six minutes or how quickly they rise from a chair—provides tangible evidence of functional benefit. The Functional Tests domain, FT, captures performance-based motor and cognitive assessments in standardized units like meters and seconds. Mapping FT separately from subjective questionnaires ensures objective physical endpoints are clean and ready for primary efficacy modeling.
Clinical Variable Mapping Scope & Service Execution
Captures performance-based physical, neurological, and cognitive functional assessments (e.g., 6-Minute Walk Test, Timed Up and Go, grip strength, gait speed).
Precision medicine relies on matching targeted therapies to somatic mutations, gene fusions, copy number alterations, and tumor mutational burden. The Genomics Findings domain, GF, standardizes NGS, PCR, and microarray outputs using official HGNC gene symbols and HGVS variant nomenclature. Clean GF mapping integrates molecular biomarkers directly into your submission package for companion diagnostic and subgroup approvals.
Clinical Variable Mapping Scope & Service Execution
Standardizes somatic and germline molecular alterations—SNVs, indels, copy number variations (CNVs), gene fusions, TMB, and MSI status—from NGS, PCR, and microarray assays.
Regulatory auditors routinely verify that enrolled patients met protocol eligibility rules and that screen failures were properly documented. The Inclusion/Exclusion Criteria Not Met domain, IE, records only the specific criteria a screened subject failed, linked directly to your Trial Inclusion/Exclusion design. Proper IE mapping eliminates false-positive eligibility flags and keeps screen-failure auditing effortless.
Clinical Variable Mapping Scope & Service Execution
Records only the specific eligibility criteria that a screened subject failed to satisfy, enabling regulatory auditing of screen failures and protocol waivers.
For biologics, monoclonal antibodies, and vaccines, anti-drug antibodies can neutralize efficacy or trigger hypersensitivity reactions. The Immunogenicity Specimen Assessments domain, IS, structures tiered testing—screening, confirmatory, titer, and neutralizing assays—linked to pharmacokinetic timepoints. Clean IS mapping enables clear regulatory incidence tables and correlation with drug exposure.
Clinical Variable Mapping Scope & Service Execution
Captures anti-drug antibody (ADA) screening, confirmatory, neutralizing antibody (NAb), and titer results essential for biologics, mAbs, and vaccine clinical programs.
The Laboratory Test Results domain, LB, is typically the largest dataset in a clinical submission, combining central and local pathology panels across dozens of visits. Mapping LB harmonizes diverse lab units into uniform CDISC standard units, recalculates reference ranges proportionally, and derives NCI-CTCAE toxicity grades. Clean LB mapping prevents unit-mismatch artifacts and protects liver and renal safety signals.
Clinical Variable Mapping Scope & Service Execution
Harmonizes central and local clinical pathology panels (hematology, chemistry, urinalysis, coagulation) into CDISC standard units with reference ranges and toxicity grades.
In infectious disease trials, identifying the exact causative pathogen and quantifying viral or bacterial load is fundamental to proving antimicrobial efficacy. The Microbiology Specimen domain, MB, standardizes culture results, Gram stains, and quantitative PCR viral loads using controlled organism nomenclature. Mapping MB cleanly links isolated pathogens to downstream antimicrobial susceptibility testing.
Clinical Variable Mapping Scope & Service Execution
Standardizes pathogen identification, Gram stains, viral load PCR assays, and culture findings from infectious disease and microbiome clinical studies.
Histopathology diagnoses, tumor grades, and immunohistochemistry biomarker scores like PD-L1 expression dictate patient stratification in oncology and pathology trials. The Microscopic Findings domain, MI, standardizes tissue biopsy evaluations, staining methods, and both categorical and percentage IHC scores. Proper MI mapping ensures pathology endpoints are fully traceable to biopsy sites and imaging records.
Clinical Variable Mapping Scope & Service Execution
Captures histopathology, cytology, immunohistochemistry (IHC H-scores, PD-L1 TPS/CPS), and biopsy tissue evaluations across oncology and pathology studies.
Therapies targeting osteoporosis, arthritis, or neuromuscular disorders depend on precise bone mineral density and joint mobility tracking. The Musculoskeletal System Findings domain, MK, standardizes DEXA T-scores, Z-scores, and goniometric range-of-motion measurements with exact anatomical locations and laterality. Clean MK mapping preserves longitudinal measurement consistency across imaging centers.
Clinical Variable Mapping Scope & Service Execution
Standardizes bone mineral density (DEXA T-scores/Z-scores), joint range-of-motion (goniometry), and radiographic joint space narrowing assessments.
Changes in organ size—such as spleen volume reduction in myelofibrosis or liver volume changes in metabolic disease—serve as critical clinical endpoints. The Morphology domain, MO, captures macroscopic organ dimensions, volumes, and anatomical circumferences across CT, MRI, and ultrasound modalities. Mapping MO keeps non-tumor anatomical measurements structured and distinct from oncology lesion tracking.
Clinical Variable Mapping Scope & Service Execution
Captures macroscopic anatomical dimensions, organ volumes, body circumferences (waist/hip), and structural morphology measurements from imaging or physical inspection.
Knowing which pathogen infected a patient is only half the story; regulators also require proof of antibiotic susceptibility and resistance patterns. The Microbiology Susceptibility domain, MS, standardizes Minimum Inhibitory Concentrations, zone diameters, and susceptible-intermediate-resistant interpretations. Mapping MS with direct links to parent isolates in MB enables clear microbiological eradication analyses.
Clinical Variable Mapping Scope & Service Execution
Captures antimicrobial susceptibility testing—Minimum Inhibitory Concentration (MIC), zone diameter, and S/I/R interpretations—for pathogens identified in MB.
Neurology and neurodegenerative trials rely on specialized biomarkers ranging from amyloid and tau PET SUVR ratios to nerve conduction velocities and EEG metrics. The Nervous System Findings domain, NV, standardizes these neuro-imaging and electrophysiological outputs by brain region and laterality. Clean NV mapping anchors complex neuroimaging readouts to clinical cognitive endpoints.
Clinical Variable Mapping Scope & Service Execution
Standardizes neurological and neuroimaging findings including brain PET SUVR (amyloid/tau), MRI volumetric lesions, EEG parameters, and nerve conduction velocities.
Ophthalmology trials require strict eye-level precision because a treatment may target one eye while the fellow eye serves as an internal control. The Ophthalmic Examinations domain, OE, standardizes visual acuity letters, intraocular pressure, and retinal OCT thickness with mandatory left/right laterality. Mapping OE cleanly prevents eye-assignment errors and protects monocular efficacy endpoints.
Clinical Variable Mapping Scope & Service Execution
Captures visual acuity (ETDRS letters, Snellen), intraocular pressure (IOP), optical coherence tomography (OCT retinal thickness), and slit-lamp exam findings.
Establishing safe and effective dosing regimens depends on accurate bioanalytical drug and metabolite concentration profiles. The Pharmacokinetics Concentrations domain, PC, standardizes plasma, serum, and urine concentrations alongside lower limits of quantitation and exact elapsed times since dosing. Proper PC mapping preserves raw below-limit-of-quantitation flags while preparing clean numeric series for pharmacokinetic modeling.
Clinical Variable Mapping Scope & Service Execution
Standardizes bioanalytical drug and metabolite concentrations in plasma, serum, urine, or CSF alongside exact sampling times relative to dosing.
Baseline and longitudinal physical exams detect clinical abnormalities that imaging or lab panels might miss. The Physical Examination domain, PE, standardizes head-to-toe assessments across body systems and highlights clinically significant changes. Mapping PE with cross-checks against Medical History and Adverse Events ensures no clinically significant exam finding goes unexplained during regulatory review.
Clinical Variable Mapping Scope & Service Execution
Captures head-to-toe physical examination assessments across standardized body systems (Cardiovascular, Respiratory, Neurological, Skin) and clinical significance flags.
Summary pharmacokinetic metrics—such as Cmax, Tmax, AUC, and elimination half-life—form the quantitative foundation of clinical pharmacology sections in regulatory labels. The Pharmacokinetics Parameters domain, PP, standardizes non-compartmental and compartmental PK parameters with reference dose timestamps. Clean PP mapping enables seamless bioequivalence and exposure-response comparisons.
Clinical Variable Mapping Scope & Service Execution
Stores non-compartmental and compartmental PK parameters (CMAX, TMAX, AUCLST, AUCIFO, HL) derived from PC concentration profiles.
Patient-Reported Outcomes and clinical rating scales like EORTC QLQ-C30, EQ-5D, and PHQ-9 capture how patients actually feel and function—a top priority for both regulators and payers. The Questionnaires domain, QS, enforces strict CDISC QRS test codes and instrument names across every item and summary score. Proper QS mapping prevents terminology validation warnings and preserves validated scoring integrity.
Clinical Variable Mapping Scope & Service Execution
Standardizes validated Patient-Reported Outcomes (PROs), ClinROs, and ObsROs (e.g., EORTC QLQ-C30, EQ-5D-5L, PHQ-9, HAM-D, MMSE) per CDISC QRS supplements.
In asthma, COPD, and interstitial lung disease trials, pulmonary function metrics like FEV1 and FVC are primary approval endpoints. The Respiratory System Findings domain, RE, standardizes spirometry volumes, flow rates, and diffusing capacity alongside sitting posture and pre- versus post-bronchodilator timepoints. Clean RE mapping separates absolute liters from percent-predicted scores for unambiguous respiratory analysis.
Clinical Variable Mapping Scope & Service Execution
Captures pulmonary function tests (PFTs) including spirometry (FEV1, FVC, FEV1/FVC ratio, PEF), diffusing capacity (DLCO), and plethysmography lung volumes.
Documenting childbearing potential, contraception compliance, and reproductive status is a core safety requirement in clinical trials involving potentially teratogenic therapies. The Reproductive System Findings domain, RP, standardizes reproductive assessments separately from laboratory pregnancy tests. Mapping RP cleanly ensures regulatory safety reviewers can verify risk-minimization compliance across all enrolled cohorts.
Clinical Variable Mapping Scope & Service Execution
Standardizes reproductive history, childbearing potential status, contraception methods, pregnancy test outcomes, and menstrual cycle parameters.
In oncology and autoimmune trials, standardized disease response criteria—such as RECIST 1.1, Lugano, or ACR20—determine whether a therapy wins regulatory approval. The Disease Response domain, RS, structures target, non-target, and overall timepoint responses while separating investigator reads from Blinded Independent Central Review. Clean RS mapping ensures primary objective response and progression-free survival endpoints are audit-proof.
Clinical Variable Mapping Scope & Service Execution
Captures oncology and chronic disease response evaluations (RECIST 1.1, iRECIST, Lugano, RANO, ACR20/50/70) across target, non-target, and overall timepoint responses.
Baseline demographic attributes that fall outside the fixed Demographics schema—such as education level, dominant hand, blood type, or Fitzpatrick skin type—often serve as vital covariates. The Subject Characteristics domain, SC, captures these subject-level attributes in a standardized vertical structure. Mapping SC prevents unnecessary clutter in Supplemental Demographics while keeping baseline covariates easily accessible.
Clinical Variable Mapping Scope & Service Execution
Captures baseline subject attributes not included in Demographics (DM)—such as education level, marital status, dominant hand, Fitzpatrick skin type, or blood group.
Overall survival is the gold-standard endpoint in oncology and cardiovascular outcomes trials, requiring accurate tracking long after study treatment ends. The Subject Status domain, SS, records longitudinal survival follow-up contacts and vital status. Proper SS mapping aligns last-known-alive dates with end-of-study disposition dates, ensuring accurate right-censoring in Kaplan-Meier survival analyses.
Clinical Variable Mapping Scope & Service Execution
Tracks longitudinal vital/survival status (ALIVE, DEAD, LOST TO FOLLOW-UP) during long-term post-treatment survival follow-up in oncology and cardiovascular outcomes trials.
Objective tumor shrinkage is tracked across multiple visits by measuring target and non-target lesions on CT or MRI scans. The Tumor/Lesion Results domain, TR, standardizes longest diameters, sum of diameters, and lesion states across imaging modalities and independent readers. Clean TR mapping guarantees exact lesion-ID linkage back to baseline tumor identification, making tumor burden kinetics transparent.
Clinical Variable Mapping Scope & Service Execution
Captures longitudinal measurements of target and non-target lesions (longest diameter, perpendicular diameter, sum of diameters, lesion status) across imaging visits.
Before a tumor can be measured over time, every target, non-target, and newly emerging lesion must be uniquely cataloged. The Tumor/Lesion Identification domain, TU, establishes the master lesion registry with anatomical sites, laterality, and lesion classifications. Rigorous TU mapping ensures 1:1 referential integrity with Tumor Results and cleanly flags new lesions driving progressive disease.
Clinical Variable Mapping Scope & Service Execution
Establishes the baseline and new-lesion registry identifying each target, non-target, and new tumor lesion, its anatomical site, classification, and imaging modality.
Urology and renal studies rely on physiological functional metrics—such as post-void residual bladder volume and peak urinary flow rate—that differ from chemical urinalysis. The Urinary System Findings domain, UR, isolates these urodynamic and ultrasound measurements with standardized units. Mapping UR separately from laboratory urinalysis keeps physiological bladder function endpoints clean and well-structured.
Clinical Variable Mapping Scope & Service Execution
Captures urological and urodynamic measurements including post-void residual (PVR) bladder volume, urinary flow rate (QMAX), and bladder diary metrics.
Blood pressure, heart rate, respiratory rate, temperature, weight, and BMI are fundamental safety parameters collected at nearly every visit. The Vital Signs domain, VS, harmonizes global site measurements into uniform SI units—Celsius, centimeters, and kilograms—while preserving subject posture and cuff location. Clean VS mapping eliminates unit-conversion errors and enables accurate orthostatic and hemodynamic safety reviews.
Clinical Variable Mapping Scope & Service Execution
Standardizes physiological vital signs (systolic/diastolic blood pressure, pulse rate, respiratory rate, temperature, height, weight, BMI, SpO2) with position and location.